MecLock Safeguards

280 www.strasser-gmbh.com - sales@strasser-gmbh.com MecLock_Katalog_2025_CAT_2505-10_EN_INT Technical Annex Evaluation device for safety switch PT10 0V TST UB CES-AZ-AES-01B 104770 J SH1 O1 Read- head 1 H11 Trans- ponder H12 EUCHNER DIA 23 24 13 14 Y1 Y2 S K2 + K1 + Activation of the teach-in operation with jumper on J, 0V. UB, 0V Power supply J, 0V Jumper for teach-in operation H11/H12 Read head 1 connection SH1 Read head 1 shield TST Test input O1 Semiconductor monitoring output DIA Diagnostic output 13, 14 Connection for relay contact A, safety relay enable 23, 24 Connection for relay contact B, safety relay enable Y1, Y2 Feedback loop S Start button connection (monitoring of the falling edge) Features The PT10 safety switch is connected to the control system using the evaluation unit. The evaluation unit has two enable paths and signal outputs for each connected read head. • 1 read head can be connected • 2 safety outputs (relay contacts, with 2 internally connected NO contacts per output) • Start button and feedback loop can be connected • Unicode • Plug-in connection terminals • Category 4 / PL e according to EN ISO 13849-1 Technical data Operating range Repeat accuracy R according to EN 60947-5-2 Max. 10 % Operating and display elements LED display Safety contacts status, status LED, diagnostics LED Electrical connection values Fuse external (operating voltage U B ) 0.25…8 A Connection cross section plug-in screw / spring terminals 0.25…2.5 mm² Operating voltage DC U B 21…24…27 V DC regulated, residual ripple < 5 % EMC protection requirements Acc. to EN 60947-5-3 Current consumption (with relay energized) 150 mA (without consideration of load currents at the signalling outputs)

RkJQdWJsaXNoZXIy MTIxMzQ=