MecLock Safeguards

278 www.strasser-gmbh.com - sales@strasser-gmbh.com MecLock_Katalog_2025_CAT_2505-10_EN_INT Technical Annex Terminal box EPS11 Features The terminal box is installed in the control cabinet and the 24‑volt signal line is clamped on.This enables online diagnostics directly at the control cabinet without plugging directly into the servo motor. The use of a terminal box is recommended if the servo motor is in a location that is difficult to access, e.g. due to its height. Due to the fixed installation, a separate terminal box is required for each servomotor. • Plug-in screw terminals for signal connections • USB interface converter with galvanic isolation • Integrated fuse for 24 V supply • Indicator light for 24 V • DIN rail module, 22.5 mm wide VT BU RD GN YE WH-GN BN-GN WH RD-BU GY-PK YE-BN WH-YE WH-GY GY-BN GY BK PK 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 16 17 A B C D F G H I K L M E S T U R N O P DO1 DO2 DO3 DO4 DIN1 DIN2 DIN3 DIN4 DIN5 DIN6 SINH ST O1 PE +24V GND 24V F1 RS232 USB X1- F1 2A Standard cable colors signal cable Input logic supply +24V optional Safe Torque Off DI... : Digital input DO...: Digital output SINH: Start inhibitor STO1: Safe Torque Off GND: Ground PE: Protective earth