MecLock Safeguards
247 MecLock_Katalog_2025_CAT_2505-10_EN_INT www.strasser-gmbh.com - sales@strasser-gmbh.com The values listed above were determined according to Strasser factory standard. The values serve only as an indication, may differ in a particular case depending on the configuration and do not represent a binding delivery characteristic. Closing time SFV.F-B30-P-2350 in [s] * (control unit quick run S20 at 6 bar) (Time for closing direction!) Length protective field** in [mm] 3200 1.5 1.8 2.0 2.3 2.5 2.8 3.0 3.3 3.5 3000 1.5 1.8 2.0 2.3 2.5 2.8 3.0 3.3 3.5 2800 1.5 1.8 2.0 2.3 2.5 2.8 3.0 3.3 3.5 2600 1.5 1.8 2.0 2.3 2.5 2.8 3.0 3.3 3.5 2400 1.5 1.8 2.0 2.3 2.5 2.8 3.0 3.3 3.5 2200 1.5 1.8 2.0 2.3 2.5 2.8 3.0 3.3 3.5 2100 1.5 1.8 2.0 2.3 2.5 2.8 3.0 3.3 3.5 2000 1.4 1.6 1.9 2.1 2.4 2.6 2.8 3.1 3.3 1900 1.3 1.6 1.8 2.0 2.2 2.4 2.7 2.9 3.1 1800 1.3 1.6 1.8 2.0 2.2 2.4 2.7 2.9 3.1 1700 1.3 1.6 1.8 2.0 2.2 2.4 2.7 2.9 3.1 1600 1.3 1.6 1.8 2.0 2.2 2.4 2.7 2.9 3.1 1500 1.3 1.6 1.8 2.0 2.2 2.4 2.7 2.9 3.1 1400 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 1300 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 1200 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 600 700 800 900 1000 1100 1200 1300 1400 Stroke in [mm] *) Pane material PETG, PC, aluminum composite panel or aluminum **) Length protective field = dimension A + dimension B + dimension C With the option GFA (ducted exhaust air) the closing time increases by approx. 0.2 s. With a reduced operating pressure of 5 bar, the opening time for large and heavy guards increases by approx. 10‑20 % compared to the closing time. Please specify operating pressure reductions when ordering.