MecLock Safeguards
246 www.strasser-gmbh.com - sales@strasser-gmbh.com MecLock_Katalog_2025_CAT_2505-10_EN_INT The values listed above were determined according to Strasser factory standard. The values serve only as an indication, may differ in a particular case depending on the configuration and do not represent a binding delivery characteristic. Technical Annex Closing times vertical safety window SFV.F-B30-P-2350 Closing time SFV.F-B30-P-2350 in [s] * (control unit standard S10 at 6 bar) (Time for closing direction!) Length protective field** in [mm] 3200 2.6 3.0 3.4 3.8 4.3 4.7 5.1 5.5 6.0 3000 2.6 3.0 3.4 3.8 4.3 4.7 5.1 5.5 6.0 2800 2.6 3.0 3.4 3.8 4.3 4.7 5.1 5.5 6.0 2600 2.6 3.0 3.4 3.8 4.3 4.7 5.1 5.5 6.0 2400 2.6 3.0 3.4 3.8 4.3 4.7 5.1 5.5 6.0 2200 2.6 3.0 3.4 3.8 4.3 4.7 5.1 5.5 6.0 2100 2.6 3.0 3.4 3.8 4.3 4.7 5.1 5.5 6.0 2000 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 5.6 1900 2.3 2.6 3.0 3.4 3.8 4.2 4.5 4.9 5.3 1800 2.3 2.6 3.0 3.4 3.8 4.2 4.5 4.9 5.3 1700 2.3 2.6 3.0 3.4 3.8 4.2 4.5 4.9 5.3 1600 2.3 2.6 3.0 3.4 3.8 4.2 4.5 4.9 5.3 1500 2.3 2.6 3.0 3.4 3.8 4.2 4.5 4.9 5.3 1400 2.0 2.4 2.7 3.1 3.4 3.7 4.1 4.4 4.8 1300 2.0 2.4 2.7 3.1 3.4 3.7 4.1 4.4 4.8 1200 2.0 2.4 2.7 3.1 3.4 3.7 4.1 4.4 4.8 600 700 800 900 1000 1100 1200 1300 1400 Stroke in [mm] *) Pane material PETG, PC, aluminum composite panel or aluminum **) Length protective field = dimension A + dimension B + dimension C With the option GFA (ducted exhaust air) the closing time increases by approx. 0.2 s. With a reduced operating pressure of 5 bar, the opening time for large and heavy guards increases by approx. 10‑20 % compared to the closing time. Please specify operating pressure reductions when ordering.
Made with FlippingBook
RkJQdWJsaXNoZXIy MTIxMzQ=