MecLock Safeguards

163 MecLock_Katalog_2025_CAT_2505-10_EN_INT www.strasser-gmbh.com - sales@strasser-gmbh.com S10 Step 8 Speed MB10 Step 7 Material panel Step 10 Safety switch Code Position closed P10 PT10 Step 11 Safety switch E96 Step 9 Energy connection ALENA Step 12 Color Step 9 Energy connection Code Top right, outlet right (only step 5 “R3”) E96 Top left, outlet left (only step 5 “R4”) E74 Position for outlet of pneumatic lines and electric wires, unguided. Approximately 2–3 m long from the outlet; non-terminated E74 E96 E74 Side view left DEEN01 – … Step 13 + 14 Labeling + Options P10 Step 10 not selectable Step 11 Safety switch type Code Euchner CES-A-LNN-SC M8 / CES-A-BBN* PT10 Euchner CES-I-AP-U-C04-SK M8 / CES-A-BBN-C04 PT12 Euchner CES-I-AP-U-C04-USI M12 / CES-A-BBN-C04 PT14 Pilz PSEN cs3.1p M8 / PSEN cs3.1 PT20 Pilz PSEN cs3.1 M12/8-0.15m / PSEN cs3.1 PT25 Schmersal RSS260-D-ST M8 / RST260-1 PT32 Sick STR1-SASM0AC5 M12 PT50 *) An external evaluation unit is required for this type. Matching evaluation units see accessories on p .229. Connection cable length safety switch 10 m. The remaining cable length for the safety switch integration de- pends on the selected stroke and the cable outlet position. Step 12 Color Surface, gloss level Code Aluminum natural anodized ALENA RAL color (4-digit number) smooth, glossy xxxxGLGLZ Contact bar in RAL 1003 signal yellow, smooth glossy only. (Overview RAL colors see p. 218) Step 13 Labeling Code German, English, Strasser logo DEEN01 Language 1, Language 2, Strasser logo xxxx01 Language 1, Language 2, without logo xxxx00 xx = 2-digit ISO country code (see p. 220) e.g. DEFR01 =Warnings in German and French and logo Proximity switch cylinder Code Closed NZ10 Open NZ20 Closed and open NZ30 The proximity switch cylinder (magnetic proximity switch on the pneumatic cylinder) determines the corresponding end positions of the piston rod of the pneumatic cylinder. Proximity switch type Code Festo SMT-8M NZT10 Connection cable approx. 10 m long from outlet position. Ducted exhaust air Code Silencer GFA10 The silencer reduces the exhaust noise of the S10/S20 control unit. Further information about single configuration steps and closing times can be found in the appendix starting on p .211 . Appropriate accessories can be found in the appendix on p .223. Step 14 – Options Interlock Code Internal control, pneumatically operated, without safety switch Z2P100 External control, electrically operated, with ifm GF711S safety switch Z2E280 External control, electrically operated, with Sick IME2S12-04B4DC0 safety switch Z2E290

RkJQdWJsaXNoZXIy MTIxMzQ=