MecLock Safeguards
109 MecLock_Katalog_2025_CAT_2505-10_EN_INT www.strasser-gmbh.com - sales@strasser-gmbh.com AE202621 Step 10 Actuator P10 Step 13 not selectable SB50 Step 11 not selectable PT10 Step 14 Safety switch Step 11 Motor control Code Open, close, intermediate position (half stroke) SB50 E74M2K01A Step 12 Actuator position ALENA Step 15 Color Step 10 Actuator Code Actuator 32/3 (230 V) with PLC, i = 10 AE202621 Actuator 32/3 (230 V) with PLC, i = 15 AE202721 Actuator 32/3 (230 V) with Profinet, i = 10 AE222621 Actuator 32/3 (230 V) with Profinet, i = 15 AE222721 Actuator 32/3 (230 V) with PLC STO, i = 10 AE232621 Actuator 32/3 (230 V) with PLC STO, i = 15 AE232721 Actuator 32/3 (230 V) with Profinet STO, i = 10 AE252621 Actuator 32/3 (230 V) with Profinet STO, i = 15 AE252721 Actuator 433/4 (400 V) with PLC, i = 7.5 AE262521 Actuator 433/4 (400 V) with Profinet, i = 7.5 AE282521 Actuator 433/4 (400 V) with PLC STO, i = 7.5 AE292521 Actuator 433/4 (400 V) with Profinet STO, i = 7.5 AE312521 Actuator 433/4 (400 V) with PLC, i = 10 AE262621 Actuator 433/4 (400 V) with Profinet, i = 10 AE282621 Actuator 433/4 (400 V) with PLC STO, i = 10 AE292621 Actuator 433/4 (400 V) with Profinet STO, i = 10 AE312621 Achievable speeds depending on stroke, dimensions and pane material see p. 239/ 240/ 241 . Step 13 Safety switch Code Position closed P10 Step 14 Safety switch type Code Euchner CES-A-LNN-SC M8 / CES-A-BBN* PT10 Euchner CES-I-AP-U-C04-SK M8 / CES-A-BBN-C04 PT12 Euchner CES-I-AP-U-C04-USI M12 / CES-A-BBN-C04 PT14 Pilz PSEN cs3.1p M8 / PSEN cs3.1 PT20 Pilz PSEN cs3.1 M12/8-0.15m / PSEN cs3.1 PT25 Schmersal RSS260-D-ST M8 / RST260-1 PT32 Sick STR1-SASM0AC5 M12 PT50 *) An external evaluation unit is required for this type. Matching evaluation units see accessories on p .229. Connection cable length safety switch 10 m. The remaining cable length for the safety switch integration de- pends on the selected stroke and the cable outlet position. Step 15 Color Surface, gloss level Code Aluminum natural anodized ALENA RAL color (4-digit number) smooth, glossy xxxxGLGLZ Contact bar in RAL 1003 signal yellow, smooth glossy only. (Overview RAL colors see p. 218) Step 16 Labeling Code German, English, Strasser logo DEEN01 Language 1, Language 2, Strasser logo xxxx01 Language 1, Language 2, without logo xxxx00 xx = 2-digit ISO country code (see p .220) e.g. DEFR01 =Warnings in German and French and logo DEEN01 – … Step 16 + 17 Labeling + Options Further information about single configuration steps and closing times can be found in the appendix starting on p .211 . Appropriate accessories can be found in the appendix on p .223. Step 17 – Options Interlock Code External control, electrically operated, with ifm GF711S safety switch Z2E280 External control, electrically operated, with Sick IME2S12-04B4DC0 safety switch Z2E290 Step 12 Actuator position Code Top left, actuator position left 0° E74M2K01A Top right, actuator position right 0° E96M2K01B The power connections are located directly on the actuator. All con- nection cables are available separately as accessories. For available cable lengths, see accessories on p.230. Side view left (detail) E74M2K01A (operator side) Front view (drive position left) Front view (drive position right) Side view right (detail) E96M2K01B (machine side)
Made with FlippingBook
RkJQdWJsaXNoZXIy MTIxMzQ=