MecLock Safeguards

226 www.strasser-gmbh.com - sales@strasser-gmbh.com MecLock_Catalog_2021_CAT_2101-04_EN_INT Technical Annex Control of electrically driven safeguards Connection diagram servomotor 32/3 PLC interface Motor supply N (230V AC) Motor supply L (230V AC) PE X2 Power connector X2 1 6 PE 5 4 3 2 L Ballast Ballast Do not connect N PE Do not connect X1 Signal connector Out 1 In 1 Out 4 Out 3 Out 2 (In 3) In 2 (In 4) 0V +24V In 6 In 5 Safe stop Start inhibitor only with option STO (safe torque off) } X1 A F G EDCB L K I H ONM UT SRP Do not connect RS232 - Reference potential Do NOT connect to GND!) RS232 - Interface RxD RS232 - InterfaceTxD Do not connect WP1 W1 VT BU RD RDBU WH BNGN WHGN YE GN GY GYBN WHGY WHYE YEBN GYPK BK PK WP1 interrupts RS232 connection! W2 BN YEGN BK GY BU DE-9 Connect external ballast resistor to this pins Axle in motion Record selection 1 Position reached Error Enable, reference run and error acknowledge Start Internal wiring: X5-2 „B2 NO In“ internal wired to X1-H "ln 4" X5-4 „B1 NO In“ internal wired to X1-G "ln 3" Record selection 2 Logic supply +24V DC 2A GND Immediate stop (continuous signal high) Referencing (rising edge) Ready * Power supply available, enable available, no errors * X5 Sensor In X5 1 5 4 3 2 + B1 NO In - B2 NO In Sensor B2 Referencing XS3 1 - BN 3 - BU 4 - BK 4 3 2 1 XS1 1 - BN 4 3 2 1 XS2 1 - BN 4 3 2 1 Connection box Part No. 030418 WH 2 - WH BN BU BK WY5 Bero cableM12 4x0.34x XS5 1 - BN 3 - BU 4 - BK 4 3 2 1 3 - BU 4 - BK 3 - BU 4 - BK K1 + 86 85 - 87a 87 30 WS1 Cable M12 –M12 PUR 3x0.34 WS2 Cable M12 –M12 PUR 3x0.34 WS3 Cable M12 –M12 PUR 3x0.34 1 4 3 XS3.1 M12 87 86 30 87a 85 Relay K1 1 3 4 1 3 4 BU XS1.1 M12 1 3 4 BK XS2.1 M12 S1 Quick stop Tape switch BU BK S2 Quick stop Tape switch Caution! Ballast connections wire No. 3 and 4 insulate if not used. No voltage counter, otherwise the servo drive will be damaged! Quick stop function servomotor Sensor reference Note: Connection to the safety switch and the optional position sensors are not detailed in this electrical connection plan. The software ServoLink for the adaptation of the driving data sets and motor parameters is available together with the programming cable WP1 as an accessory (see p.178) . The records are controlled via the PLC interface. Quick stop function servomotor: When the MecLock protection system is activated, the closing door leaf or protective field is stopped mechanically without overrun. Since an immediate stop of the electric drive is not possible as quickly as with the mechanical MecLock protection system, slip or overload clutches are used to decouple the drive train from the locked door leaf or protective field and to avoid damage to the gear unit and servo motor. The quick stop function, which is triggered by a ground circuit or an actuated band switch, then automatically stops the still running servomotor and triggers a homing run. Sensor reference: The safeguard references itself automatically via the built-in reference sensor if the quick stop input becomes “Low”, a previous error has led to the loss of the reference position or the power supply of the logic part of the servomotor has been interrupted. Additional tubular fixed resistor (optional): For very heavy safeguards and very short down- times, a tubular fixed resistor may need to be installed (see p.231) . Input Function Information In1 (24V) Release Permanent signal In2 (24V) Start Positive edge starts selected set In3 (24V) Quick stop Do not switch from outside (internal use) In4 (24V) Reference Do not switch from outside (internal use) In5 (24V) + In6 (0V) Open Record 1 In5 (0V) + In6 (24V) Close Record 2 In5 (24V) + In6 (24V) Intermediate position Record 3 (Standard = 1/2 stroke)

RkJQdWJsaXNoZXIy MTIxMzQ=